Electronic level detector, PNP/NPN, Switching signal: IO-link, G1/2 sealing cone, Connector M12x1, 4-pin, Medium temperature: -40...100°C (oil), -40...100°C (water).
Factory setting - hydrous media.
IFM LMT100 (LMACE-A12E/QSKG/0/US).
Volume discounts
Quantity | Price | You Save |
---|---|---|
5 | 171,74 € | Up to 175,88 € |
10 | 155,19 € | Up to 517,30 € |
Data sheet
Sensor shape | Cylindrical |
Material | Stainless steel |
Product type | Sensor for point level detection |
Cable length | without cable |
Connector | M12x1 |
Number of contacts | 4 |
Switching function | Normally open/closed, (programmable NO/NC) |
Output type | PNP/NPN |
Power supply voltage | 18-30 VDC |
Operating temperature | -40°C ... +85°C |
Degree of protection | IP69K |
More info
Product characteristics
Number of inputs and outputs | Number of digital outputs: 2 |
Factory setting | hydrous media |
Process connection | threaded connection G 1/2 sealing cone |
Application
Special feature | Gold-plated contacts | ||
Media | Liquids; viscous media; powder | ||
Cannot be used for | See the operating instructions, chapter "Function and features". | ||
Probe length[mm] | 11 | ||
Tank pressure |
|
||
MAWP (for applications according to CRN)[bar] | 40 |
Oil | |
---|---|
Medium temperature[°C] | -40...100 |
Medium temperature short time[°C] | -40...150; (1 h) |
Water | |
---|---|
Medium temperature[°C] | -40...100 |
Medium temperature short time[°C] | -40...150; (1 h) |
Electrical data
Operating voltage[V] | 18...30 DC |
Current consumption[mA] | < 50 |
Protection class | III |
Reverse polarity protection | yes |
Measuring principle | capacitive |
Inputs / outputs
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
Total number of outputs | 2 |
Output signal | switching signal; IO-Link |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC[V] | 2.5 |
Permanent current rating of switching output DC[mA] | 100 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range
Factory setting | hydrous media |
Response times
Response time[s] | < 0.5 |
Interfaces
Communication interface | IO-Link | ||||
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
SDCI standard | IEC 61131-9 | ||||
Profiles | Smart Sensor: Process Data Variable; Device Identification | ||||
SIO mode | yes | ||||
Required master port type | A | ||||
Process data analogue | 1 | ||||
Process data binary | 2 | ||||
Min. process cycle time[ms] | 2.3 | ||||
Supported DeviceIDs |
|
Operating conditions
Ambient temperature[°C] | -40...85 | |||
Note on ambient temperature |
|
|||
Storage temperature[°C] | -40...85 | |||
Protection | IP 68; IP 69K |
Tests / approvals
EMC |
|
||||||
Shock resistance |
|
||||||
Vibration resistance |
|
||||||
MTTF[years] | 223 | ||||||
UL approval |
|
Mechanical data
Weight[g] | 169.5 |
Dimensions[mm] | Ø 30 / L = 113 |
Materials | stainless steel (316L/1.4404); PEEK; PEI; FKM |
Materials (wetted parts) | PEEK; surface characteristics: Ra < 0,8 / Rz 4 |
Process connection | threaded connection G 1/2 sealing cone |
Displays / operating elements
Display |
|
Remarks
Pack quantity | 1 pcs. |
Electrical connection
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |