KFD2-PT2-EX1 Universal Temperature Converter. - 1-channel isolated barrier; - 24 V DC supply (Power Rail); - Thermocouple, RTD, potentiometer or voltage input; - Current output 0/4 mA ... 20 mA; - Sink or source mode; - Line fault (LFD) and sensor burnout detection; Pepperl+Fuchs KCD2-UT2-Ex1. Code: 225696.
Switch Amplifier KFD2-SR2-EX2.W. - 2-channel isolated barrier;- 24 VDC supply (Power Rail);- Dry contact or NAMUR inputs;- Relay contact output;- Line fault detection (LFD);- Reversible mode of operation;- Up to SIL 2 acc. to IEC 61508/IEC 61511. Pepperl+Fuchs KFD2-SR2-EX2.W. Code: 203355
KFD2-PT2-EX1 Potentiometer Converter. - 1-channel isolated barrier;- 24 V DC supply (Power Rail);- Potentiometer input;- Voltage output 0 V ... 10 V;- Lead resistance compensation adjustment;- Accuracy 0.05%;- Up to SIL 2 acc. to IEC/EN 61508. Pepperl+Fuchs KFD2-PT2-EX1. Code: 072018.
- 1-channel isolated barrier;- 24VDC supply (Power Rail);- Dry contact or NAMUR inputs;- Usable as signal splitter (1 input and 2 outputs);- Relay contact output;- Fault relay contact output;- Line fault detection (LFD);- Reversible mode of operation;- Up to SIL 2 (SC 3) acc. to IEC/EN 61508. Pepperl+Fuchs KFD2-SR2-Ex1.W.LB. Code: 203351.
- 1-channel signal conditioner;- 24 V DC supply (Power Rail);- Level sensing input;- Adjustable range 1kΩ ... 150kΩ; - Relay contact output;- Fault relay contact output;- Adjustable time delay up to 10s; - Minimum/maximum control;- Line fault detection (LFD); Pepperl+Fuchs KFD2-ER-1.W.LB. Code: 217735.
Brass nickel plated, Thread M12x1.5, Sealing range 3-8 mm, Temperature range -20...+60 °C, Protection IP68 up to 15bar. Certified according to ATEX: Zone 1, Zone 2, Zones 21 and 22.
Brass nickel plated, Thread M20x1.5, Sealing range 6-14 mm, Temperature range -20...+60 °C, Protection IP68 up to 15bar. Certified according to ATEX: Zone 1, Zone 2, Zones 21 and 22.
Channels: 1-channel isolated barrier Power Supply: 24 V DC (Power Rail) Input: Dry contact or NAMUR inputs Output: Relay contact Mounting: DIN rail Protection Rating: IP20 Pepperl+Fuchs KCD2-SR-EX1.LB Code: PF.70112151