Inductive sensor NCB1,5-8GM25-N0-V1
Item code: PF.128867
Condition: New product
Manufacturer: PEPPERL+FUCHS
M8 size, NAMUR NC, Sn=1.5mm, flush, 2-wire, connector M12x1, 4-pin, Stainless steel 1.4305 / AISI 303 housing, IP67.
Pepperl+Fuchs NCB1,5-8GM25-N0-V1
Code: PF.128867
1 Item
Data sheet
Sensor shape | Cylindrical |
Housing (mounting) size | M8x1 |
Material | Stainless steel |
Rated operating distance | 1,5 mm |
Sensor length | 48,5 mm |
Connector | M12x1 |
Number of contacts | 2 |
Switching function | Normally Closed (NC) |
Installation | Flush |
Output type | NAMUR |
Power supply voltage | 8.2 V (Ri approx. 1 kΩ) |
Operating temperature | -25°C ... +100°C |
Degree of protection | IP67 |
Sensor type | Inductive sensors |
More info
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 1.5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.215 mm | |
Actual operating distance | 1.35 ... 1.65 mm typ. | |
Reduction factor rAl | 0.22 | |
Reduction factor rCu | 0.19 | |
Reduction factor r304 | 0.65 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) | |
Switching frequency | 0 ... 2000 Hz | |
Hysteresis | 1 ... 10 typ. 3 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | yes | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | ≤ 1 mA | |
Switching state indicator | Multihole-LED, yellow | |
Functional safety related parameters | ||
MTTFd | 3430 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
|
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
|
Approvals and certificates | ||
IECEx approval | ||
Equipment protection level Ga | IECEx PTB 11.0037X | |
Equipment protection level Gb | IECEx PTB 11.0037X | |
Equipment protection level Da | IECEx PTB 11.0037X | |
Equipment protection level Mb | IECEx PTB 11.0037X | |
ATEX approval | ||
Equipment protection level Ga | PTB 00 ATEX 2048 X | |
Equipment protection level Gb | PTB 00 ATEX 2048 X | |
Equipment protection level Da | PTB 00 ATEX 2048 X | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0452 | |
CCC approval | ||
Hazardous Location | 2020322315002256 | |
NEPSI approval | ||
NEPSI certificate | GYJ16.1393X | |
EAC conformity | TR CU 012/2011 | |
Marine approval | DNVGL TAA00001A5 | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Connection type | Connector plug | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | LCP | |
Degree of protection | IP67 | |
Connector | ||
Threading | M12 x 1 | |
Number of pins | 4 | |
General information | ||
Use in the hazardous area | see instruction manuals |
Recommended related products
-
In Stock