Inductive proximity switch IFL 5-18-10P

Item code: SC.101169211

Condition: New product

Manufacturer:

  • Design M18x1;
  • Brass enclosure;
  • Active area - Plastic;
  • DC 3-wire;
  • Sn=5mm;
  • Flush;
  • Cable 2m;
  • IP67.

Schmersal 101169211

1 Item

79,39 € tax excl.

Data sheet

Sensor shape Cylindrical
Housing (mounting) size M18x1
Material Nickel plated brass
Rated operating distance 5 mm
Sensor length 55 mm
Cable length 2 m
Connector Cable
Number of contacts 3
Switching function Normally Open (NO)
Installation Flush
Power supply voltage 10-30 VDC
Operating temperature -25°C ... +70°C
Degree of protection IP67
Sensor type Inductive sensors

More info

Ordering data

Product type description

IFL 5-18-10P

Article number (order number)

101169211

EAN (European Article Number)

4030661295220

eCl@ss number, version 12.0

27-27-40-01

eCl@ss number, version 11.0

27-27-01-01

eCl@ss number, version 9.0

27-27-01-01

ETIM number, version 7.0

EC002714

ETIM number, version 6.0

EC002714

Approvals - Standards

Certificates

CCC

General data

Standards

DIN VDE 0660-208

EN IEC 60947-5-2

Housing construction form

Cylinder, thread

Installation conditions (mechanical)

flush

Enclosure material

Brass

Enclosure coating material

nickel-plated

Active area

Plastic

Material of the nuts

Brass

Gross weight

85 g

General data - Features

Integral system diagnostics, status

Yes

Number of cable wires

3

Mechanical data

Tightening torque of nuts, maximum

18 Nm

Mechanical data - Switching distances according EN IEC 60947-5-3

Nominal switching distance Sn

5 mm

Mechanical data - Connection technique

Termination

Cable

Length of cable

2 m

Wire cross-section

0.14 mm2

Material of the Cable mantle

PVC

Mechanical data - Dimensions

ISO thread of the sensor

M18

width across flats

24 BK

Length of sensor

53 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Protection class

0

Electrical data

No-load supply current I0, maximum

3.4 mA

Rated operating voltage

10 ... 30 VDC

Operating current

200 mA

Switching element

Normally open contact (NO)

Protection circuit integrated

inductive interference protection

Protection against polarity reversal

Surge protection

Max. fuse rating

Switching frequency, approx.

400 Hz

Electrical data - Digital Output

Voltage drop Ud, maximum

1.2 V

Current at Voltage drop Ud

0.2 A

Design of control elements

p-type

Status indication

Note (Integral System Diagnostics, status )

yellow LED

Note

Note (General)

Instead of nuts, a mounting clamp can be provided.