KCD2-UT2-Ex1 Universalus temperatūros konverteris

Prekės kodas: PF.225696

Būklė: Nauja prekė

Gamintojas:

KFD2-PT2-EX1 Universalus temperatūros konverteris. 

- 1-channel isolated barrier; 
- 24 V DC supply (Power Rail); 
- Thermocouple, RTD, potentiometer or voltage input; 
- Current output 0/4 mA ... 20 mA; 
- Sink or source mode; 
- Line fault (LFD) and sensor burnout detection; 

Pepperl+Fuchs KCD2-UT2-Ex1.

Kodas: 225696.

Šiuo metu prekės neturime

508,20 € be PVM

Charakteristikos

Produkto tipas Universalus temperatūros konverteris

Apie prekę

General specifications
Signal type Analog input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply
Connection terminals 9+, 10- or power feed module/Power Rail
Rated voltage 19 ... 30 V DC
Ripple within the supply tolerance
Power dissipation ≤ 0.98 W
Power consumption max. 0.98 W
Interface
Programming interface programming socket
Input
Connection side field side
Connection terminals 1, 2, 3, 4
RTD type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)
type Cu10, Cu50, Cu100 (P50353-92)
type Ni100 (DIN 43760)
Measuring current approx. 200 µA with RTD
Types of measuring 2-, 3-, 4-wire connection
Lead resistance max. 50 Ω per line
Measurement loop monitoring sensor breakage, sensor short-circuit
Thermocouples type B, E, J, K, N, R, S, T (IEC 584-1: 1995)
type L (DIN 43710: 1985)
type TXK, TXKH, TXA (P8.585-2001)
Cold junction compensation external and internal
Measurement loop monitoring sensor breakage
Potentiometer 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)
Voltage selectable within the range -100 ... 100 mV
Input resistance ≥ 1 MΩ (-100 ... 100 mV)
Output
Connection side control side
Connection terminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+)
Output Analog current output
Current range 0 ... 20 mA or 4 ... 20 mA
Fault signal downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)
Source load 0 ... 550 Ω
open-circuit voltage ≤ 18 V
Sink Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,
series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage.
The maximum value of the resistance is (V - 5)/0.0215 Ω.
Transfer characteristics
Deviation
After calibration Pt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection))
thermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span + 1.5 K (1.7 K for types R and S)) , includes ± 1.3 K fault of the cold junction compensation (CJC)
mV: ± (50 µV + 0.1 % of span)
potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes faults due to lead resistance))
Influence of ambient temperature Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*)
thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)), influence of cold junction compensation (CJC) included
mV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*)
potentiometer: ± 0.006 % of span/K ΔTamb*)
*) ΔTamb = ambient temperature change referenced to 23 °C (296 K)
Influence of supply voltage < 0.01 % of span
Influence of load ≤ 0.001 % of output value per 100 Ω
Reaction time worst case value (sensor breakage and/or sensor short circuit detection enabled)
mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s
Galvanic isolation
Output/supply, programming input functional insulation, rated insulation voltage 50 V AC
There is no electrical isolation between the programming input and the supply.
The programming cable provides galvanic isolation so that ground loops are avoided.
Indicators/settings
Display elements LEDs
Configuration via PACTware
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibility NE 21:2012
EN 61326-3-2:2008
Degree of protection IEC 60529:2001
Protection against electrical shock UL 61010-1:2004
Ambient conditions
Ambient temperature -20 ... 70 °C (-4 ... 158 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass approx. 100 g
Dimensions 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
Height 119 mm
Width 12.5 mm
Depth 114 mm
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificate BASEEFA 13 ATEX 0102 X
Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I
Input [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Inputs terminals 1, 2, 3, 4
Voltage Uo 9 V
Current Io 13.1 mA
Power Po 30 mW
Analog outputs, power supply, collective error
Maximum safe voltage 250 V (Attention! This is not the rated voltage.)
Interface
Maximum safe voltage 250 V (Attention! The rated voltage is lower.), RS 232
Certificate BASEEFA 13 ATEX 0103 X
Marking Ex-Hexagon II 3G Ex nA IIC T4 Gc
Galvanic isolation
Input/Other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
UL approval
Control drawing 116-0379 (cULus)
IECEx approval
IECEx certificate IECEx BAS 13.0057X
IECEx marking [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.